50 screening questions for a Robotics Field Service Engineer
Experience questions only. Every one asks about cells the candidate brought up, faults they chased, repairs they made or calls they took.
A robotics field service engineer is the person a customer calls when a cell is down. Day to day that means getting to a plant, pulling fault logs off a FANUC, KUKA, ABB or Universal Robots controller, deciding whether the problem is mechanical, electrical, software or the customer's own tooling, and getting the line running again before the shift ends. The same person commissions new cells, runs FAT at the integrator's shop and SAT on the customer's floor, masters a robot after a motor or reducer swap, touches up programs on the teach pendant, chases fieldbus faults between the robot, the PLC and the safety controller, and writes the report that explains what happened.
A hiring manager for this role is not trying to find out whether the candidate knows what a teach pendant is. They want to know how many cells the person has brought up alone, which failures they have diagnosed with a plant manager standing behind them, whether they can read a safety circuit and a fieldbus trace, how they handle spares and travel, and whether customers ask for them by name. The 50 questions below go after exactly those things. None of them can be answered from a manual.
Cells and robots you have supported6 questions
Which robot brands and controllers have you serviced hands-on (FANUC R-30iB, KUKA KR C4 or KR C5, ABB IRC5 or OmniCore, UR e-Series), and roughly how many robots of each? Must have
Listen for: real counts by brand, not a brand list
Which applications have those cells run: welding, material handling, machine tending, palletizing, dispensing, grinding or finishing? Which did you support most? Important
Listen for: depth in one or two applications
Which cell did you support the longest, and what did you learn about it that was not in the documentation? Important
Listen for: tacit knowledge of a real installation
What is the largest installation you have supported, by robot count or line length, and what made it different from a single cell? Nice to know
Listen for: interlocks between cells, problems of scale
Which end-of-arm tooling, vision system or peripheral gave you more service calls than the robot itself? Important
Listen for: honest view of where failures actually live
Have you worked on cells in regulated or high-consequence settings (aerospace, defense, medical, food)? What changed about how you worked? Nice to know
Listen for: documentation, access, validation habits
Troubleshooting under pressure9 questions
Describe the last time you were called to a cell that was down with production waiting. What was the fault, what did you check first, and how long until it ran? Must have
Listen for: a method, a time and the real root cause
Tell me about a fault where the first alarm pointed at the wrong thing. How did you find the real cause? Must have
Listen for: not trusting the alarm, isolating systematically
Which intermittent fault took you the longest to catch, and what finally caught it? Important
Listen for: logging, trending, patience and a real catch
Have you traced a fault to a cable or connector (dress pack, encoder cable, harness in a flex loop)? How did you prove it? Important
Listen for: wiggle tests, continuity, swapping, wear patterns
Describe a fault that turned out to be the customer's process rather than the robot: part variation, fixture wear, upstream equipment. How did you handle that conversation? Important
Listen for: correct diagnosis plus tact with the customer
Which diagnostics do you actually pull on a call (controller logs, servo diagnostics, fieldbus diagnostics, PLC cross-reference), and which one solved a case for you? Important
Listen for: specific tools tied to a specific solve
Have you been wrong on a diagnosis in front of a customer? What happened next? Important
Listen for: honesty, recovery, what they changed
Tell me about a problem you fixed remotely, by phone or screen share, through the customer's hands. Nice to know
Listen for: clear instruction, patience, knowing the limits
Which repair did you refuse to do on site because it was unsafe or outside your competence, and what did you do instead? Nice to know
Listen for: judgment and escalation
Mechanical repair and mastering6 questions
How many motor, reducer or gearbox replacements have you done, on which axes, and which one went wrong? Must have
Listen for: counts, axis specifics, a lesson
Walk through your last mastering or calibration after a repair. Which method did you use (zero-position marks, fixture, single-axis, vision or touch-up), and how did you verify the TCP afterward? Must have
Listen for: the right method for the brand, plus verification
Describe a repeatability problem in the field. What did you measure, what did you suspect, and what was it actually? Must have
Listen for: backlash, mounting, thermal or tooling, confirmed with data
What wear signs have you learned to catch before failure: grease analysis, backlash, noise, temperature, current draw? Give a case where you caught one. Important
Listen for: a real early catch from preventive checks
Tell me about a collision or crash. What did you inspect, what did you replace, and how did you decide the arm was fit to run? Important
Listen for: inspection sequence, mastering check, documentation
Which preventive maintenance task do customers most often skip, and what have you seen it cost them? Nice to know
Listen for: grease, batteries or filters, with a real consequence
Controls, fieldbus and safety9 questions
Describe a fieldbus fault you fixed (EtherNet/IP, PROFINET, DeviceNet, EtherCAT). What were the symptoms, and how did you isolate it? Must have
Listen for: diagnostic or packet evidence, not guesswork
Have you solved a problem where the robot, the PLC and the safety controller each pointed at the other? How did you prove where the fault was? Must have
Listen for: cross-system reasoning backed by evidence
Which safety PLCs and safety functions have you worked with (dual-channel E-stops, light curtains, safety scanners, safe speed and position zones)? Give a case where you commissioned or repaired one. Must have
Listen for: specific hardware and a real commissioning or repair
Tell me about a time a customer asked you to bypass or loosen a safety function. What did you do? Important
Listen for: refusal, an alternative, documentation
How much PLC work have you done yourself (reading ladder, cross-referencing I/O, small logic changes), and on which platforms? Important
Listen for: honest depth on Rockwell, Siemens or others
Describe an I/O or handshake problem between the robot and a peripheral. How did you find it? Important
Listen for: signal tracing, timing, forcing I/O with care
Which program change did you make on the pendant that fixed a recurring problem, and how did you document it? Important
Listen for: touch-up or logic change, backups, change notes
Have you recovered a controller from a lost or corrupted backup or a dead battery? What did it take? Nice to know
Listen for: image backups, mastering data, backup discipline learned
What have you learned about vision or sensor integration from fixing it in the field? Nice to know
Listen for: lighting, calibration drift, real fixes
Commissioning, FAT and SAT7 questions
How many cells have you commissioned from power-on to production, and which one took the longest to sign off? What was the open item? Must have
Listen for: real counts and a real SAT punch list
Walk through a FAT you ran or witnessed. What did the acceptance criteria include, and what failed? Must have
Listen for: cycle time, repeatability, safety checks, failures found
Describe an SAT where the cell behaved differently on the customer's floor than at the integrator. What changed, and how did you fix it? Important
Listen for: utilities, parts, environment or network differences
What is the biggest gap you have found between the integrator's drawings or program and the cell in front of you? Important
Listen for: as-built discipline and how they closed the gap
Tell me about a cycle time target you had to hit during commissioning. What did you change to get there? Nice to know
Listen for: path, motion settings, logic, measured gain
How have you handed a cell over to the customer's maintenance team? What did you leave them with? Nice to know
Listen for: training, backups, spares list, documentation
What startup problem do you now check for on every commissioning because it bit you once? Nice to know
Listen for: a specific habit tied to a real event
Spares, MTTR and service operations6 questions
How did you decide which spares to carry in your vehicle or stock at a customer site? What ran out at the wrong moment? Must have
Listen for: a data-driven spares list and a real stockout
What was your typical MTTR on the cells you supported, and what moved it most: diagnosis time, parts, travel, access? Must have
Listen for: a number and what drives it
Describe a service report you wrote that a customer or your own team later relied on. What did it contain? Important
Listen for: root cause, parts used, open items, clear writing
How have you handled a parts lead time that kept a customer down for days? Important
Listen for: workarounds, loaners, communication
Have you recommended a retrofit or upgrade (controller, cables, safety) to a customer? What was the case, and did it happen? Nice to know
Listen for: service-to-sales awareness and the outcome
What service tools do you refuse to travel without, and which job taught you that? Nice to know
Listen for: specific tools tied to real jobs
Customers, travel and judgment7 questions
Which customer asks for you by name, and why? Nice to know
Listen for: trust earned for a specific reason
Tell me about the angriest customer you have faced on site. What did you say in the first five minutes? Important
Listen for: calm, listening, a plan
What travel load have you carried (share of time on the road, overnights, international trips, on-call rotation), and what did you find sustainable? Important
Listen for: realistic numbers and self-knowledge
Describe a job where you had to choose between a quick fix now and a proper fix later. What did you choose, and why? Important
Listen for: risk reasoning and customer communication
Which safety near-miss have you had on a plant floor, and what do you do differently now? Important
Listen for: a real event and a specific change
How do you keep up with controller software versions and new options across brands? Give an example where it mattered. Nice to know
Listen for: a real habit and a real example
What do you tell a new field engineer before their first solo call? Nice to know
Listen for: distilled experience, practical priorities
What the record answers before the call
Most of these questions can be answered from a candidate's career record before anyone books a call. When the record was built in Achieved, each answer cites the claim it came from, and the claim points to its source, so a reviewer can check the cell, the brand and the number. The questions the record cannot answer, and the judgment questions near the end, go to the person on the first call. Candidates can build a record once and reuse it; employers can paste a posting and get a set like this for their own opening.